+86-18901131178
Sitemap |  RSS |  XML

TLMS3000 Transmission Line Condition Monitoring System

Through the collection, analysis and display of transmission line temperature, humidity, wind speed, wind direction, leakage current, ice condition, video images and other digital information, combined with PMS, the TLMS3000 transmission line condition monitoring system realizes transmission line operation condition monitoring and equipment condition diagnosis evaluation.
Product Description

 

1. Product Introduction of The TLMS3000 Transmission Line Condition Monitoring System

 

Through the collection, analysis and display of transmission line temperature, humidity, wind speed, wind direction, leakage current, ice condition, video images and other digital information, combined with PMS, the TLMS3000 transmission line condition monitoring system realizes transmission line operation condition monitoring and equipment condition diagnosis evaluation.

 

2. Product Feature And Application of The TLMS3000 Transmission Line Condition Monitoring System

 

Micro Meteorological Monitoring Devices

Real-time measurement of temperature, humidity, wind speed, wind direction, rainfall, air pressure, light radiation, etc., as a basis for the prediction of natural disasters and the evaluation of the state of wire icing, wire vibration, etc.
Tlmu-EVS02A /02B/05/06/07 Microweather Sensor

TLMU-IDC01 Integrated Data Acquisition Unit

 

Video and Image Monitoring Devices

Real-time video or image information of wire, tower or surrounding environment is collected by timing or remote control, so that the on-site situation of transmission line is presented intuitively in front of our eyes.

TLMU-VGS01/02/03/04 High Definition Camera

TLMU-VGC-G/T/W/E Video Image Data Terminal

 

Conductor Icing Monitoring Devices

Through the measurement of wire tension, dip Angle, wire load calculation, combined with micrometeorology and video monitoring, realize the evaluation of wire icing state.
TLMU-IAS01Dip Angle Sensor (ISM433 or Zigbee wireless)

TLMU-TFS01 Tension Sensor

TLMU-EVS02A/02B Microweather Sensor

TLMU-IDC01 Integrated Data Acquisition Unit
TLMU-VGS01/02/03/04 HD Camera

TLMU-VGC-G/T/W/E Video and Image Data Terminal

 

Conductor Temperature Monitoring Devices

The real-time temperature monitoring is an important basis for the calculation of transmission capacity and margin.
TLMU-LTS01 Wire Temperature Sensor (ISM433 or Zigbee wireless)

TLMU-IDC01 Integrated Data Acquisition Unit

 

Conductor Wind Deviation Monitoring Devices

By monitoring the wind deflection Angle and inclination Angle of wire (or insulator string), the minimum electrical clearance of wire is calculated to prevent the occurrence of wind flashover.
TLMU-IAS01/02 Dip Angle Sensor (ISM433 or Zigbee wireless)

TLMU-IDC01 Integrated Data Acquisition Unit

 

Conductor Vibration Monitoring Devices

By monitoring the wind deflection Angle and inclination Angle of wire (or insulator string), the minimum electrical clearance of wire is calculated to prevent the occurrence of wind flashover.

TLMU-IAS01 Dip Angle Sensor (ISM433 or Zigbee wireless)

TLMU-IDC01 Integrated Data Acquisition Unit

 

Conductor Galloping Monitoring Devices

Built-in three-axis gyroscope and three-axis accelerometer can accurately measure the dancing amplitude and frequency of the wire, as well as motion parameters such as acceleration, speed and attitude Angle, so as to describe the dancing track of the wire detection point.
TLMU-LGS01 Traverse Dancing Sensor (ISM433 or Zigbee wireless)

TLMU-IDC01 Integrated Data Acquisition Unit

 

Tower Inclination and Vibration Monitoring Devices

By measuring the linear inclination Angle and transverse inclination Angle of the tower, the tower inclination degree can be evaluated. By measuring the three-dimensional acceleration of the tower, the damage and destruction caused by tower vibration can be prevented.
TLMU-IAS02 Inclination Sensor
TLMU-VS02 Vibration Sensor

TLMU-IDC01  Integrated Data Acquisition Unit

 

Insulator Contamination Monitoring Devices

The pollution degree of insulators can be evaluated by monitoring the equivalent salt density and ash density of insulators, as well as temperature and humidity monitoring.
TLMU-U01 Insulator Detection Terminal

TLMU-IDC01 Integrated Data Acquisition Unit

 

3. Product Details of The TLMS3000 Transmission Line Condition Monitoring System

 

 

4. Product Qualification of The TLMS3000 Transmission Line Condition Monitoring System

 

 

5. Deliver, Shipping And Serving of The TLMS3000 Transmission Line Condition Monitoring System

 

Depending on the size of the order and the shipping distance (The usual delivery time is 1 month), and the warranty is 1 year. Besides, the terms of transaction are FOB full payment.

 

6. FAQ

 

Q: What's your lead time?

A: Generally, the whole production cycle from raw material to finished product takes 15-30 days, but we can ship within 7 days and we can change according to quantity or other conditions as we have raw material stock semi-finished products.

 

Q: Are you a trading company or a manufacturer?

A: We are the original manufacturer, so we have the advantage of price.

 

Q: How long is the product life?

A: Our products are maintenance-free and sealed, using advanced technology, long service life, no problems in normal use.

 

Q: How to use the products?

A: Easy to use, please follow the instructions.

 

Q: Are your products' parameters real?

A: All our parameters are real, maximum quantity, competitive price and long life cycle.

 

Q: Do you have any OEM service?

A: If you purchase a certain quantity, we can also print your logo on the battery case.  

 

Q: What is your MOQ?

A: The minimum order quantity is measured according to the product you order.

 

Q: What are your payment terms?

A: The payment shall be communicated in advance, and the contract shall be drawn up according to the time limit stipulated in the contract.

 

Q: What is your product standardization?

A: First according to The Chinese standard, then according to the international export standard.

 

Q: How long will it take you to provide us with the design?

A: Depending on your design requirements, it depends on how difficult it is.

 

Send Inquiry
For inquiries about our products or pricelist, please leave your email to us and we will be in touch within 24 hours.

Verify Code